Comparison of allergen responses based on the TRUE Test and IQ Chamber system in Korean patients
- 주제(키워드) Concordance , IQ® Chamber , Korean standard series , Patch test , TRUE Test®
- 후원정보 Kennedy's Disease Association
- 등재 SCIE, SCOPUS
- 발행기관 John Libbey Eurotext
- 발행년도 2017
- URI http://www.dcollection.net/handler/ewha/000000155766
- 본문언어 영어
- Published As http://dx.doi.org/10.1684/ejd.2017.3139
- 저작권 이화여자대학교 논문은 저작권에 의해 보호받습니다.
초록/요약
Background: A comparison between responses to allergens based on the TRUE Test®(TT) and IQ® Chamber (IQC) in Europeans has been previously reported, however, no such study has been performed in Asians. Objectives: To compare allergen responses using the TT and IQC (using the Korean standard series) in order to gather more information regarding the positive response rates for each allergen and the clinical value of IQC. Materials & methods: Suspected contact dermatitis patients were enrolled and tested with 18 allergens using the TT and IQC. Results: The test was performed in 214 patients. Simultaneous positive results for both tests were recorded in 242 cases (positive concordance rate: 66.7%). IQC yielded more positive results. Allergens with a high positive concordance rate were nickel sulphate (82.1%), thimerosal (78.6%), and p-phenylenediamine (73.3%). IQC mostly showed similar or higher positive rates than TT, with high concordance. Conclusions: We recommend the IQC method as a screening test in patients with suspected contact dermatitis. To compensate for possible false positive results, careful history taking and a different patch test should be performed when appropriate. © 2017, John Libbey Eurotext. All rights reserved.
more