The aim of this study is to evaluate the actual insulation performance of the apartment building PC (precast concrete) envelope to which steel tying materials are additionally installed between structures and hollow-core slabs are applied. Through three-dimensional steady-state heat transfer simulation, the energy performance and condensation risk of each envelope composed of RC (reinforced concrete) and PC having the same legal U-factor and insulation method were compared and analyzed. As results, it was found that the effective U-factor and temperature difference ratio of the RC and PC envelopes were very similar, indicating that the energy performance and condensation risk were almost the same. The effective U-factor of both the RC and PC envelopes was about 30 to 90% higher than the legal U-factor, indicating a large heat loss due to thermal bridges. Therefore, in order to improve energy performance, it is necessary to remove thermal bridges in both the RC and PC envelopes.

more

초록/요약

본 연구는 구조체 간 결속부자재가 추가 설치되고 중공 슬라브가 적용되는 공동주택 PC(precast concrete)조 외피의 실제 단열성능 수준을 평가하는 것을 목적으로 한다. 3차원 정상 상태 전열해석을 통해 동일한 법적 열관류율과 단열공법을 가진 벽식 RC(reinforced concrete)조와 PC조로 구성된 각 외피의 에너지 성능 및 결로방지성능을 비교 분석하였다. 그 결과, 벽식 RC조와 PC조 외피의 유효 열관류율(U-factor)과 온도차이비율(TDR)이 매우 유사하여 에너지 성능과 결로방지성능 역시 거의 유사한 것으로 판단된다. 벽식 RC조 및 PC조 외피의 유효 열관류율은 법적 열관류율보다 약 30-90% 높아, 열교로 인한 열손실이 매우 크게 나타낸다. 따라서 에너지 성능을 개선하기 위해서는 벽식 RC조와 PC조 모두 외피의 열교 방지가 필요하다.

more